Technical parameters

  • Single-channel pipetting accuracy
    Pipette Measuring range random error Systematic error
    µL %D µL %CV µL
    Flex 1-Channel Pipette (1–50 µL) 1 10 50 ±8.00%
    ±1.50%
    ±1.25%
    0.08 µL
    0.15 µL
    0.625 µL
    ±7.00%
    ±0.50%
    ±0.40%
    0.07µl
    0.05µl
    0.20µl
    Flex 1-Channel Pipette (5–1000 µL) 550 200 1000 ±5.00%
    ±0.50%
    ±0.50%
    ±0.50%
    0.25 µL
    0.25 µL
    1.00 µL
    5.00 µL
    ±2.50%
    ±0.30%
    ±0.15%
    ±0.15%
    0.125 µL
    0.15 µL
    0.30 µL
    1.50 µL
  • 8-channel pipetting accuracy
    Pipette Measuring range random error Systematic error
    µL %D µL %CV µL
    Flex 8-Channel Pipette (1–50 µL) 1 10 50 ±10.00%
    ±2.50%
    ±1.25%
    0.10 µL
    0.25 µL
    0.625 µL
    ±8.00%
    ±1.00%
    ±0.60%
    0.08µl
    0.10µl
    0.30µl
    Flex 8-Channel Pipette (5–1000 µL) 550 200 1000 ±8.00%
    ±2.50%
    ±1.00%
    ±0.70%
    0.40 µL
    1.25 µL
    2.00 µL
    7.00 µL
    ±4.00%
    ±0.60%
    ±0.25%
    ±0.15%
    0.20 µL
    0.30 µL
    0.50 µL
    1.50 µL
  • 96-channel pipetting accuracy
    Tip size volume %D %CV
    50μl 5μl ±10% ±5%
    50μl 50μl ±2.5% ±1.25%
    200μl 200μl ±1.5% ±1.25%
    1,000μl 1,000μl ±1.5% ±1.5%

FAQ

Frequently Asked Questions about Opentrons Flex and OT-2 Products,Please click here.

  • Can Flex pipettes detect liquid levels?

    Yes, Flex pipettes contain pressure sensors for detecting liquid level. These sensors are included in channels A1 and H12 of 96-channel pipettes, and in the outermost channels (1 and 8) of 8-channel pipettes.

  • Has pipette installation/removal been improved?

    Yes, this installation/removal process is now guided by a touchscreen display on the deck. Through optimization, customers can load/unload pipettes more easily and achieve better alignment.

  • Do Opentrons Flex multichannel pipettes have independent aspiration volume control?

    Opentrons Flex 8-channel and 96-channel pipettes aspirate and dispense with all channels aspirating or dispensing the same volume of liquid. Aspiration volume cannot be controlled independently across channels.

  • Can I use OT-2 pipettes and tips with Opentrons Flex?

    OT-2 pipettes and OT-2 pipette tips are not compatible with Opentrons Flex. OT-2 pipette tip cones and Flex pipette tip cones are constructed differently and are not cross-compatible. OT-2 tip boxes/refills are also not compatible with the Flex.