科研加速 | Flex Prep全自动移液工作站特惠来袭!

Check the Details

The next generation of laboratory automation has arrived

Contact Us

Opentrons Flex, your perfect partner

Unlike other laboratory automation systems available today, Opentrons Flex is an innovative invention that offers high flexibility and versatility, effectively reducing manual operations.

Watch Video

Powerful automation capabilities for your applications

  • NGS library preparation
  • PCR
  • protein purification
  • Nucleic acid extraction
  • Liquid packaging

NGS library preparation

With the Flex NGS Workstation, you can automate NGS library preparation on demand, increasing efficiency, reducing errors, and saving hands-on time. You can use any popular reagent on the market to automate all pre-sequencing workflows, including fragmentation- and tagging-based library preparation. 

Precision in a desktop pipetting workstation

  • Accuracy 8% at 1 µL
  • Accuracy 5% at 1 µL
  • deck trough 2 deck slots + 4 dedicated deck slots for tips and labware
  • size 87 × 69 × 84 cm (width, depth, height)

Complete specifications

Easily replaceable pipettes

We offer easily interchangeable 1-, 8-, and 96-channel pipettes for precise and reliable pipetting from 1 to 1000 µL.

  • single channel

    1–50 μL
    5–1000 μL

  • 8 channels

    1–50 μL
    5–1000 μL

  • 96 channels

    5–1000 μL

Flex adapts to your experimental workflow

Choose a protocol that suits your workflow and experience to precisely customize your experimental workflow.

  • protocol designer

    You can create new protocols using our simple and intuitive drag-and-drop interface.

    protocol designer
  • protocol library

    You can browse a large number of open source protocols online through the online protocol library.

    protocol library
  • Python protocol API

    Write your experimental protocols using our open source Python protocol API.

    Python API
  • custom protocol

    A team of applied scientists creates optimized custom protocols for you.

    Contact us

Serve

Flexibility to provide the support you need.

Technical parameters

  • size

    87 × 69 × 84 cm / 34.25 × 27 × 33 in (width, depth, height)

    Only half your lab bench

  • weight

    88.5 Viewed / 195 Boss

  • Pipette overview

    Flex pipettes feature air displacement technology for precise pipetting from 1 to 1000 microliters

    Smart sensors enable automatic calibration, real-time positioning and error detection

    The Flex gantry can be equipped with any two Flex single-channel or 8-channel pipettes, or a single Flex 96-channel pipette.

    Flex pipettes are installation-friendly and you can easily install and replace pipettes

  • Pipette volume parameters

    Flex single-channel pipette: 1–50 µL, 5–1000 µL

    Flex 8-channel pipette: 1–50 µL, 5–1000 µL

    Flex 96-channel pipette: 5–1000 µL

  • Turn plate gripper parameters

    Opentrons Flex plate transfer grippers can transfer well plates, reservoirs and tip racks. Depending on the setup, the swiveling plate grabber can move lab supplies into deck slots, between modules, or into bins.

  • deck

    12 ANSI/SLAS compliant main deck slots (work area with access to pipette and plate grippers)

    4 additional slots for tips and laboratory supplies (positioning area, only accessible to transfer plate gripper)

    Deck can be reconfigured by removing deck troughs and replacing them with other deck fixtures, including removable bins and module trays

  • Smart touch screen

    Flex is equipped with a 7-inch LCD touch screen, which is made of anti-scratch and anti-damage LCD material. Users can complete experimental settings by simply touching the screen.

  • Connectivity

    802.11 ac/a/b/g/n dual-band (2.4/5GHz), USB 2.0, Ethernet

  • Camera

    Integrated camera (future customization feature)

  • Power requirements

    Power adapter input: 100-240 VAC, 50/60 Hz, 4.0 A / 115 VAC, 2.0 A / 230 VAC

  • Frame composition

    Designed with rigid steel and CNC aluminum

    The frame frames the openings for the polycarbonate side windows and front door. Allows for easy removal and integration of external equipment (e.g. robotic arms)

  • Operating temperature and relative humidity

    Recommended 20-25°C

    Recommended 40-60%RH

  • Single channel accuracy and precision
    Pipette Measuring range random error Systematic error
    μl %D μl %CV μl
    1–50 µL 1 10 50 ±8.00%
    ±1.50%
    ±1.25%
    0.08µl
    0.15µl
    0.625µl
    ±5.00%
    ±0.50%
    ±0.40%
    0.05µl
    0.05µl
    0.20µl
    5–1000 µL 5 50 200 ±5%
    ±0.5%
    ±0.5%
    0.25µl
    0.25µl
    1.00µl
    ±2.50%
    ±0.30%
    ±0.15%
    0.125µl
    0.15µl
    0.30µl
  • sterility

    Designed with a full polycarbonate shell to limit exposure. Opentrons Flex is not a sterile environment. Optional HEPA/UV accessories are under development.

  • Viscous liquid

    For guidance on automating the handling of viscous liquids, see our application notes. This data was developed on OT-2, and the practical results are still useful for Opentrons Flex.

    Viscous liquid handling automation with Opentrons OT-2

  • API compatibility

    Interface with any product that has an API

    Opentrons software is open source and users can adapt the software as needed to interface with other products. While all integrations are possible, they all require custom code work, i.e. most customers will need to write custom libraries and install packages that don't come with the robot.

    learn more
  • operating system

    Windows 10, macOS 10.10 or higher, Ubuntu 12.04 or higher.

    Opentrons app
  • Tip compatibility

    Using Opentrons Flex Tips and Opentrons Flex Filter Tips

    Opentrons guarantees the performance of Opentrons Flex tips designed specifically for Opentrons Flex. Opentrons Flex tips do not have a uniform hole size. Opentrons cannot guarantee the performance of third-party tips.

  • Labware Compatibility

    You can use common supplies already in our lab supplies library, or add your own. If your lab consumables fit Opentrons Flex but are not in the lab consumables library, you can add them using our Consumables Creator or have our team assist you in adding them.

    learn more
  • Warranty

    Comes with one year warranty

  • Certification

    Certification completed (CE, FCC, NRTL, CB, ISO 9001)

    Not certified/validated (IVD, GMP)

  • packing list

    Flex robot

    calibration module

    trash can

    Spare deck clamp

    Spare deck trough, replacement waste bin

    Power and zone IEC cables

    Ethernet cable

    lifting handle

    tool kit

FAQ

Frequently Asked Questions about Opentrons Flex and OT-2 Products,Please click here.

  • Do I need to know programming knowledge to use Opentrons Flex?

    No knowledge of programming is required to use the Opentrons platform. You can create protocols using Opentrons' concise and easy-to-understand protocol design tools. Additionally, our application engineering technical team can build custom protocols for you.

  • What services can I enjoy by purchasing Opentrons Flex?

    On-site installation, remote service and annual preventive maintenance.

  • What kind of labware is Opentrons Flex compatible with?

    Like OT-2, Flex It can support any orifice plate compatible with automation and compliant with ANSI/LAS standards, as well as a wide variety of EP tubes and nut centrifuge tubes, including centrifuge tubes with a capacity of up to 50 mL. You can view all supported laboratory equipment in our Laboratory equipment library.

  • Do I need a computer to connect to Opentrons Flex? Or can I operate directly on the touch screen?

    Users do not need a computer connection to run the protocol. After creating the protocol on your computer, upload it to Flex where it can be operated via the touch screen.

  • Can I use OT-2 pipettes with Opentrons Flex?

    No, OT-2 pipettes are not compatible with Opentrons Flex.

  • Are the Opentrons Flex side panels removable?

    Yes, the side windows and front door of the Opentrons Flex are removable.

  • Does Opentrons Flex have collision detection?

    Opentrons Flex will detect collisions by comparing the actual movement of the embedded motor to the expected movement. For example, if the robot expects 2 motor rotations, but only completes 1 due to a collision (stopping motor movement), the robot will detect the difference between the expected movement and the actual movement. An error message will then appear telling you that recalibration is required.

  • Can I use one computer to control multiple Opentrons Flex?

    Can! The same applies to OT-2.

  • How many saved protocols can be displayed on Opentrons Flex?

    Users can save up to 8 protocols on the Opentrons Flex touch screen.

  • How much clearance is there in the rear of the Opentrons Flex for power and ventilation?

    20 cm (8 inches) of side and back clearance for cables, USB connections, and to dissipate exhaust air from instruments such as thermal cycling modules or temperature control modules.

Flex adapts to your automated experimental process

Welcome to make an appointment for an online demonstration to discuss your experimental needs with a team of professional application scientists.

Book a demo
Contact Us

The experienced service team and strong production support team provide customers with worry-free order services.