Flex应用专题 | 解锁蛋白质谱前处理自动化的无限潜能

Check the Details

Opentrons Flex PCR Workstation Laboratory Installation Steps

In modern biological laboratories, the use of automated equipment is becoming more and more common, and the Opentrons Flex PCR workstation, as an efficient experimental tool, can significantly improve the accuracy and efficiency of PCR experiments. This article will introduce in detail the steps for installing the Opentrons Flex PCR workstation in the laboratory to help scientific researchers successfully complete the setup and debugging of the equipment.

Opentrons Flex PCR 工作站在实验室安装的步骤

Opentrons Flex PCR Workstation

1. Environmental preparation 1. Confirm laboratory conditions: Ensure that the laboratory has a stable power supply and a suitable working environment (such as temperature, humidity, etc.). Check that the laboratory has sufficient space to install and operate the Opentrons Flex PCR Workstation. 2. Prepare necessary tools and materials: Prepare screwdrivers, wrenches and other basic tools. Ensure appropriate detergents and disinfectants are available for cleaning and disinfecting workstations.

2. Hardware assembly 1. Install the main body of the workstation: According to the hardware manual or video tutorial provided by Opentrons, assemble the main body of the workstation. Make sure all screws and fasteners are installed correctly and that the workstation is structurally sound. 2. Connect hardware components: Connect pipettes, temperature control modules, thermal cycle modules and other hardware components to the main body of the workstation. Connect cables and tubing correctly according to the instructions in the hardware manual. 3. Check the hardware status: After the assembly is completed, check whether all hardware components are installed correctly and can work normally. Special attention is paid to the calibration of the pipette and the temperature control accuracy of the thermal cycler module.

3. Software installation and configuration 1. Install Opentrons software: Download the latest software installation package from the Opentrons official website or GitHub repository. Install the required Python and Node.js environments according to the instructions in the installation package. 2. Configure Opentrons App: Download and install Opentrons App, which is a desktop application used to manage and control Opentrons robots. Configure the workstation's network connection, API services, etc. according to the instructions in the App. 3. Testing and verification: Run the sample protocol or test protocol provided by Opentrons to verify whether the installation and configuration of the workstation are correct. Check the response and performance of hardware components such as pipettes, temperature control modules, and thermal cycler modules.

4. Calibration and Debugging 1. Calibrate the pipette: Use the calibration function in the Opentrons App to accurately calibrate the pipette. Adjust the parameters of the pipette according to the calibration results to ensure that its pipetting accuracy meets the experimental requirements. 2. Debugging the thermal cycle module: Set the temperature program of the thermal cycle module and verify its temperature control accuracy. Adjust the parameters of the thermal cycle module according to the experimental results to ensure that it can meet the needs of the PCR experiment.

5. Training and operation 1. Training operators: Provide training to laboratory operators on the operation of the Opentrons Flex PCR workstation. Ensure that operators are familiar with the workstation’s functions, operating procedures, and precautions. 2. Develop operating procedures: Develop detailed operating procedures based on the actual conditions of the laboratory and the functional characteristics of the workstation. Ensure the accuracy and operability of operating procedures and provide guarantee for the accuracy and reliability of experimental results.

6. Maintenance and maintenance 1. Regular cleaning and disinfection: Clean and disinfect the Opentrons Flex PCR workstation regularly to maintain the cleanliness of its surface and internal environment. Use appropriate cleaners and disinfectants to avoid damage to workstations. 2. Check the hardware status: Regularly check the status of the workstation’s hardware components (such as pipettes, temperature control modules, thermal cycle modules, etc.). Discover and deal with potential faults or problems in a timely manner to ensure the normal operation of the workstation. 3. Update the software version: Pay attention to the official updates of Opentrons and obtain the latest software version and update instructions in a timely manner. Update the workstation's software version according to the update instructions to ensure its compatibility and stability.

Installing the Opentrons Flex PCR workstation is not complicated. Just follow the above steps carefully and you will be able to complete it smoothly. During this process, ensuring that every step is performed according to specifications will effectively improve the success rate of the experiment.

Related reading recommendations

Automated NGS library preparation e-book

How to save lab time with an automated benchtop thermal cycler

Opentrons Flex turntable gripper

Advantages of fully automatic pipetting workstations for culture medium preparation

OT-2 nucleic acid extraction workstation workflow principle

Library construction principle of fully automatic pipetting workstation

Contact Us

The experienced service team and strong production support team provide customers with worry-free order services.