Flex应用专题 | 解锁蛋白质谱前处理自动化的无限潜能
Check the Details-
article · 2025Year56Moon8Day
磁珠分选是什么
Read More -
Press release · 2025Year40Moon8Day
云端相约 | 邀您共同解锁蛋白质谱前处理自动化无限潜能
Read More -
article · 2025Year27Moon6Day
微孔板振荡器在工作站中的应用
Read More
In biological science research and experiments, protein purification is a very critical step. Opentrons Flex magnetic bead protein purification workstation has become the tool of choice for many scientific researchers because of its efficiency, flexibility and automation. However, to get the most out of this device, it is also important to correctly select and configure the required consumables. This article will introduce in detail the main consumables required by the Opentrons Flex magnetic bead protein purification workstation, aiming to help scientific researchers better prepare for experiments to ensure that the experiments proceed smoothly and obtain accurate and reliable results.
Opentrons Flex Magnetic Bead Protein Purification Workstation
1. Basic consumables 1. Magnetic beads: Function: Magnetic beads are the core consumables in magnetic bead protein purification. They can bind to target proteins and achieve separation under the action of a magnetic field. Selection criteria: Select the appropriate magnetic bead type and specification according to the specific needs of the experiment to ensure the binding efficiency and separation effect of the magnetic beads and protein. 2. Well plate: Function: The well plate is used to place samples and reagents to facilitate magnetic bead protein purification operations. Selection criteria: Select orifice plates that meet ANSI/SLAS standards to ensure compatibility with the workstation. Commonly used well plate types include 96-well plates, 384-well plates, etc. The specific selection depends on the experimental needs and the processing capacity of the workstation. 3. Pipette tips: Function: Pipette tips are used to remove and distribute liquid samples and reagents. Selection criteria: Select a tip that matches the configured pipette model to ensure the accuracy and stability of pipetting. At the same time, select the appropriate tip specifications and quantity according to experimental needs.
2. Special consumables 1. Test tubes and centrifuge tubes: Function: Test tubes and centrifuge tubes are used for sample storage, transfer and centrifugation. Selection criteria: Select test tubes and centrifuge tubes with good chemical stability and thermal stability to ensure the accuracy of experimental results. At the same time, select appropriate specifications and quantities according to experimental needs. 2. Test tube rack and centrifuge tube rack: Function: Test tube rack and centrifuge tube rack are used to place test tubes and centrifuge tubes neatly to facilitate experimental operations. Selection criteria: Select test tube racks and centrifuge tube racks that match the workstation and experimental needs to ensure the stability and safety of test tubes and centrifuge tubes. 3. Sealing film and plate sealing film: Function: Sealing film and plate sealing film are used to seal the orifice plate to prevent liquid evaporation and contamination. Selection criteria: Select sealing film and plate sealing film that meet the requirements of the workstation to ensure the sealing and stability of the orifice plate.
3. Other consumables 1. Buffer and washing liquid: Function: Buffer and washing liquid are used for sample dilution, washing and purification. Selection criteria: Select appropriate buffer and washing solution type, concentration, pH value and other parameters according to experimental needs. 2. Filter paper and cotton swabs: Function: Filter paper and cotton swabs are used to clean work surfaces, pipette tips and other tools to ensure the cleanliness and sterility of the experimental environment. Selection criteria: Select filter paper and cotton swabs with good hygroscopicity and cleaning effect to ensure the accuracy and safety of experimental operations. 3. Magnetic rods and adapters (if applicable): Function: Some models of Opentrons Flex magnetic bead protein purification workstation may require the use of specific magnetic rods and adapters to assist in the separation and purification of magnetic beads. Selection criteria: Select the appropriate magnet and adapter type based on the specific model of workstation and experimental needs.
There are many types of consumables required to configure the Opentrons Flex magnetic bead protein purification workstation, and the selection of each consumable needs to be determined based on the experimental needs and the specific requirements of the workstation. Therefore, when configuring consumables, it is recommended to carefully review the workstation's instructions and experimental guide to ensure that the selected consumables are compatible with the workstation and match the experimental requirements.
Related reading recommendations
Opentrons pipette thermal cycling module GEN2
White Paper: Opentrons High-Precision Pipettes
FLEX fully automatic pipetting workstation: comprehensive upgrade and unlimited adaptation
What toxicity testing projects is the fully automatic pipetting workstation suitable for?
Tip specifications of OT-2 nucleic acid extraction workstation
Opentrons Flex magnetic bead protein purification workstation full process introduction
The experienced service team and strong production support team provide customers with worry-free order services.